Products

SQUARE CEILING DIFFUSER

INTRODUCTION:

The diffusers are designed for ceiling applications.
They can be used for supply or extract air, together with the accessories required for various demands.

PROPERTIES:
The diffusers have fixed and straight blades.
For supply air purposes, they are characteristically suitable for horizontal air throws.
Where ‘ICoanda effect” is required, they should be installed close to the ceiling.
These diffusers are recommended for use with ceiling heights up to 4 m., with a supply air temperature difference of (+/-) 100C.
The diffuser is made of a frame and a central blade block.
The blade block is fixed to the frame by the aid of spring pins and can easly be removed / installed.
The standard sizes start from 150 x 150 mm, and go up to 600 x 600 mm with increments of 75 mm. One, two, three and four way throwing types are available

ROUND CEILING DIFFUSER

INTRODUCTION:

The diffuser can be used for ceiling or exposed duct mounting and has a fixed horizontal air pattern.

MATERIAL:

Frame and inner cones are high quality die drawing aluminum.
Blade support: Aluminum bar linkage to support inner cones together.
clamp: Spring clamp to fix inner cones to the frame by hinge bar.

FINISH:

Aluminum construction with white powder coated finish (RAL 9010) any color upon request.

TRANSFER GIRLL

INTRODUCTION:
it is a rectangular aluminum door transfer grille with fixed deflectors and can be used in commercial and industrial premises.
The grille is intended for free passage of air through doors.
The grille can have pre punched beveled holes for mounting with screws.
FUNCTION:

The grille fixed deflectors have pitch of 1″(25mm) and this space allows the air to pass freely between both sides of the grille.
Because of the specially arranged deflectors it is not possible for light to pass through.

JET NOZZLE

INTRODUCTION:

Jet nozzle designed for handling large Air volume and long throw also, suitable for horizontal and vertical
discharge application such as entrance ways, gymnasiums, swimming pools, airports…. Etc
For use ni heating or cooling applications

INNER CORE:

Drawing die high qality aluminum sheet forming

FACE BOARD PLATE:

face board plate which holding the jet nozzle diffuser in order to install it.
consist of galvanized sheet metal plate.

PERFORATED CEILING DIFFUSER

INTRODUCTION:

The Perforated Air Grille combines a inner
core of perforated aluminum or stanless steel sheet surround with a frame of 30
mm wide. This grille has a free area of approximately (16% : 50% ) which makes ti extremely effective in all air function.

FRAME:

Standard outer frames from best quality extruded aluminum alloy 6063 profile.

FACE BOARD PLATE:

Perforated faces from Galvanised steel ,or stanless steel (316)pr aluminum sheet upon request.

SWIRLDIFFUSER

INTRODUCTION:

The swirl diffuser with fixed radially arranged air control blades. This unique type of slots provide high induction “vortex” air flow projecting horizontally from the face of diffuser.
This swirling air flow produce a diffuse air distribution, with no stationary air jet resulting excellent uniformity of temperature in air conditioned space.
Swirl diffuser is suitable in area of high heat load where large quantities of cool air must be rapidly mixed with room air; areas which require high air change in a short time.
The Swirl diffuser can also be used as a
return and exhaust type device.

LINEAR SLOT DIFFUSERS

INTRODUCTION:

The And 002 Model Slot is designed to combine a high air change rate capacity with maximum flexibility in air pattern and volume control, suitable for either ceiling or sidewall applications.
Linear slot diffusers offer unobtrusive good looks together with functional efficiency.
Linear slot diffusers are particularly suited
to large open plan offices, where changing occupancy layouts demand an air distribution system that includes built in adaptability to suit the relocation of internal partitioning. Other applications include restaurants, meeting / conference rooms, atriums etc

LINEAR CEILING DIFFUSERS

INTRODUCTION:

The swirl diffuser with fixed radially arranged air control blades. This unique type of slots provide high induction “vortex” air flow projecting horizontally from the face of diffuser.
This swirling air flow produce a diffuse air distribution, with no stationary air jet resulting excellent uniformity of temperature in air conditioned space.
Swirl diffuser is suitable in area of high heat load where large quantities of cool air must be rapidly mixed with room air; areas which require high air change in a short time.
The Swirl diffuser can also be used as a
return and exhaust type device.

LINEAR BAR GRILLES

MATERIAL:

Extruded aluminum throughout.

SIZES:
Maximum single unit length 1800mm.
Above this size linear runs are supplied in multiple units for butt joining, flange alignment strips are supplied to ensure continuous line appearance.
FINISH:
Standard: White RAL 9010, or Silver RAL 9006 stove enamel.
Optional: See Ordering section details

REGISTER

DEFLECTION REGISTER:

A fully adjustable register suitable for supply or extract application.
Single deflection register have one bank of fully adjustable blades,which are held in place by high tensile spring wire. With maximum free area of around air dynamic tear drop shaped blades.
Single deflection registers are effective extract register creating minimum noise and pressure drop.
For supply, aim the blade in one direction for a target throw or spread then for a wide , gentle diffusion. It’s suitable for high side wall, soffit or duct mounting.

MATERIAL:

Extruded aluminum

ACCESS PANEL

INTRODUCTION:
Access panels are built-in accessories for ceiling. They are planted in various areas of the suspended ceiling, shaft walls or drywall partitions that requires access for constant adjustments, inspections and revisions. Ventilation ducts, electrical control outlets.
This panel is designed to fit into the structural membrane of jointless plasterboard ceiling systems, it is supplied with a beaded frame to allow for tape and jointing on site and comes complete with a fully removable flush door.
It is inserted directly into a pre-cut hole through.

FLOOR & PERFORATED FLOOR GRILL

APPLICATIONS:

Floor fixed bar aluminum grilles are used for air supply and exhaust in all kinds of low pressure air handling.

SIZES:
Available as standard in 600 x 600 m m tile replacement but can be manufactured in any size from 300 x 300 mm to 750 x 750.
The grille is manufactured from extruded aluminum (6063) The core is mounted transversely on deep flat section aluminum alloy support bars welded to the heavy section main frame.

LOUVER

INTRODUCTION:

The external louver protects the external supply and exhaust openings of  ventilation devices against moisture  penetration, and direct ingress of rain, leaves and birds.
It prevents direct views into the protected area. It is applied for improving the aesthetic impression of the exterior, which is increased by the surface finishing and the shape of blades.

MATERIAL:

Louvers are made from extruded aluminum profiles for blade and frame.

FINSIH:

Standard finish for aluminum mill or powder coated.

SAND TRAP LOUVER

APPLICATIONS:

Sand trap Louver is normally used as prefilter for fresh air intake of Air Handling Unit (AHU), Package Air Conditioning Units (PACU) and Roof Top Fresh Air Units (RTFAU).
Also for air conditioning systems and air intake in manufacturing plants
It has a degree of separation of sand and large dust particles, even in cases of high dust concentration. The sand trap louver is
designed to separate large 1 particles at low air velocities, thus avoiding excessive dust loading on conventional plant filters. The vertically arranged sections and holes for sand drainage ensure the sand trap louver is self-cleaning and maintenance-free.
It is not intended as a substitute for conventional

BALL JET NOZZLE

INTRODUCTION:

Ball Jet nozzles are used for Air conditioning system ni large rooms, in general ball jet nozzles are arranged in the side wall areas.
This is the case ni large rooms (halls, assembly rooms etc.)particularly when the distribution of air via ceiling diffusers is not possible or not practical, as that it is better to choose ball jet nozzles.
Ball Jet nozzles are arranged in the side wall areas to supply air.
When the temperature difference between the supply air and the room air changes as the season changes, making the supply air stream deflected upwards (cold air) or downwards (warm air) to mix the air
stream symmetrical and fast.

DISC VALVES

INTRODUCTION:

Round ceiling diffuser provides excellent performance in variable air volume
systems and provides a clean, smooth look for exposed duct or hard ceiling applications. Additionally, it has a center thread bar adjustable positions.

APPLICATIONS:

For supply and exhaust ventilation Air conditioning and heating.
Mounting in false ceiling or wall.
Used to arrange correct air circulation in premises.

NON RETURN DAMPERS

INTRODUCTION:

The gravity air shutter is a wall mounted device. It is composed of a set of horizontally mounted blades; they are normally closed and are free to rotate about the horizontal axis to equalize the pressure across it.
FRAME
Extruded aluminum section frame.

FRAME:

Extruded aluminum section frame.

SEAL:

Sealing foam strips on the blades where they overlap to ensure a good seal and to reduce noise

FINISH:

Standard mill finish or powder coated.

VOLUME DAMPER

INTRODUCTION:

The Volume Control Damper has been specially designed to control air flow in HVAC system where high/medium/low pressure are experienced.
These dampers are designed to operate from one control point.
The damper’s blade opening is controlled by hand locking quadrant or motor.

MATERIAL:

Extruded Aluminum or galvanized steel.

CASING:

Extruded Aluminum or galvanized steel for upper and side frames with different case depth

FIRE DAMPER

INTRODUCTION:

Fire dampers are installed in an air-distribution system, and are designed to close automatically upon detection of heat, to interrupt migratory air flow, and to restrict the passage of flame. They are required in order to maintain the required
integrity of a fire resistance assembly when ducts penetrate fire-rated walls, partitions, or floors.
Fire dampers are required b y either the model building or mechanical codes or National Fire Protection Association
(NFPA) 90A,Standard for the Installation of Air Conditioning and Ventilating Systems.

SMOKE DAMPER:

INTRODUCTION:

Smoke Dampers can be used in two different applications,where they simply close and prevent the circulation of airand smoke through duct or a ventilation opening in a smokebarrier.
Or they may be designed to control the spread of smoke using walls and floors as barriers and using the building’s HVAC system and or dedicated fans to create pressure differences. Higher pressures surround the fire area and prevent the spread of smoke from the fire zone into
other areas of the building. Smoke Dampers are motorized with electric
actuator. They may be controlled by a smoke or heat detector signal, a fire alarm signal, or in a variety of ways by the building control system to accomplish the intent of the design.

DUCT ACCESS DOOR

INTRODUCTION:
Fire dampers need inspecting and testing, coils need cleaning and controls need adjusting.
So we offer a range of duct and plenum access doors that have been designed to allow easy and convenient access to such equipment within HVAC ductwork, without compromising safety or ventilation, to meet different duct styles and application needs.
Some models feature quality double skin construction that meets SMACNA requirements, with quick simple installation and low leakage flat oval series provides premium quality that optimizes access area and ease of installation.

DUCT WORK

INTRODUCTION:
A duct system is a network of round or rectangular tubes-generally constructed of sheet metal, fiberglass board, or a flexible plasticine – wire composite – located within the walls, floors, and ceilings.
Usually, you can see only the outlet, which is a register covered with grillwork.
The purpose of a duct system is to transmit air from the central air source to the air diffusers located in the building control zones.
Figure below shows a central heating furnace connected to supply and return air ductwork.
The furnace is connected to the air plenum at the starting point.
Furnace fan/s draw air in through grilles called returns and force air through the plenum and into the conditioned space through supply registers
Scroll to Top